| Product |
Code |
Size |
Description |
| |
|
|
|
|
HYBRID CAPTURE ®2 HPV® |
|
|
|
| |
|
|
|
| Digene
HPV Test Dual Probe
Digene
HPV Test High Risk
Digene HPV Test Panel 6 member
Digene HPV Validation Panel |
5101-1096
5101-1190
5101-1024
5101-1042 |
96
96
1 set
1 set |
Digene’s Human Papillomavirus (HPV) DNA Test
is a signal amplification test using chemiluminescence for the qualitative
detection of eighteen types of HPV DNA in cervical specimens. Differentiating
between high risk types (16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58,
59, 68) from low risk HPV types (6, 11, 42, 43, 44). |
| HYBRID
CAPTURE ®2 CT/GC |
|
|
|
| |
|
|
|
| Digene
Chlamydia/Gonorrhea Test
Digene
Chlamydia Test
Digene
Gonorrhoea Test
Digene CT/GC DNA Panel |
5130-1096
5135-1050
5140-1000
5130-1116 |
96
96
96
1 set |
The Digene CT/GC, CT-ID and GC-ID Tests are
designed for the detection of Chlamydia trachmatis (CT)
and Neisseria gonorrhoea (GC) from cervical specimens collected
using the Digene Cervical Sampler or from urine specimens processed
using the Digene Urine Prep Kit for male specimens. The Digene CT/GC
DNA Test detects samples which are positive for infection. The Digene
CT-ID Test and the Digene GC-ID Test can be used following positive
CT/GC results or they can be used as stand- alone tests. |
| Digene Cervical Sampler |
5100-1050 |
50/box |
Digene’s Cervical Sampler contains
a special conical brush to collect cervical cells for Digene’s HPV,
CT/GC, CT-ID and GC-ID Tests. |
| Digene Sample Conversion Kit |
5100-1400
5100-1050 |
100 mL
1000 mL |
The Digene Sample Conversion Kit is used to
allow the HPV DNA Test to be performed on the same specimen that the
ThinPrep Pap Test is performed on. |
| Digene Urine Preparation Kit |
5130-1015 |
90 specs. |
The Digene Urine Preparation Kit for male
specimens is required to process male urine specimens for use with
any of the Digene CT/GC Tests. |
| HYBRID
CAPTURE®2 HBV |
|
|
|
| Digene
HC2 HBV DNA Test
Digene
HC2 HBV DNA Test PLUS |
6196-1230
6198-1230 |
96
96 |
The Digene Hepatitis B Virus (HBV) DNA Test
is a signal amplification test using chemiluminescence to detect and
quantify Hepatitis B viral DNA in human serum. The test detects HBV
ad and ay subtypes. Standard
test dynamic range: 1.42 X 105 to 1.7 X 109 copies/ml
(0.5 to 6000 pg/ml) using
a sample volume of 30 ml. Ultra Sensitive
dynamic range: 4.7 X 103 to 5.6 X 107 copies/ml
(0.017 to 200 pg/ml) using a sample volume of 1ml which
is concentrated by centrifugation. |
| |
|
|
|
| HYBRID
CAPTURE (HC) CMV |
|
|
|
| Digene
CMV DNA Assay |
4403-2003 |
60 |
The Digene Cytomegalovirus (CMV) DNA Test
is intended for the detection of human cytomegalovirus DNA in peripheral
white blood cells isolated from whole blood specimens collected in
EDTA. |
| |
|
|
|
|
EQUIPMENT & ACCESSORIES |
|
|
|
| |
|
|
|
|
HC2 MICROPLATE ASSAY |
|
|
|
|
EQUIPMENT |
|
|
|
| DML 2000 Microplate System-
Womens Health
incl Luminometer, Shaker,
Printer,PC, Monitor & Software
DML 2000 Microplate System-
Blood Virus
incl Luminometer, Shaker Heater,
PC, Monitor, Printer & Software
DML 2000 Luminometer
Microplate Heater
Microplate Shaker
Wash Apparatus
Expand 4 Pipettor (inc power
supply)
Expand-4 Pipettor Stand
Specimen Collection Tube Rack |
5000-1240
5000-2240
5000-1010
6000-1240
6000-2240
5030-1010
5025-1010
5025-1015
5015-1010 |
1
1
1
1
1
1
1
1
1 |
Hybrid Capture Microplate Systems are simple,
easy to use, PC-based systems designed and validated for optimal performance
with Digene's microplate tests (HPV, CT/GC & HBV). The DML 2000
Luminometer’s accuracy and compact size make it ideal for any laboratory.
After reading the luminescence from the Hybrid Capture microplate
test, the DML 2000 uploads the data to a PC for analysis. The Rotary
Shaker vortexes microplates, tube and microtube racks and other sample
containers. The shaker provides various speedsfrom 200 to 1200 rpm,
with an orbit of 3 mm. Digene’s Microplate Heater is an electronically
controlled heating unit composed of a base with dual heating elements,
an RTD block temperature sensor and a high grade aluminium heating
block. |
|
ACCESSORIES |
|
|
|
| Specimen Tubes |
5061-1001 |
1000/cs |
|
| Thin Tip Pipettes |
5076-1011 |
2000/cs |
|
| Disposable Reagent Reservoir |
5090-1010 |
100/bx |
|
| HBV Plate Sealers |
6000-0319 |
100/bx |
|
| Hybridization Plates |
6000-1203 |
100/bx |
|
| Absorbent Blot Pad |
6000-0904 |
3000/CS |
|
| Microtube Racks |
5065-1010 |
1 |
|
| Microtubes |
5060-1001 |
960 |
|
| Plate Sealers |
5070-1010 |
100 |
|
| Extra Long Pipette Tips |
5075-1011 |
720 |
|
| Screw Caps |
5080-1000 |
1000 |
|